Standalone photoelectric smoke alarm family
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
Export product-family resource
Plan procurement with Standalone Smoke Alarms for Fire Safety Management Systems: review model paths, specification inputs, evidence checks and questions to...
Direct answer
An export standalone smoke alarm detects smoke and provides a local audible warning without requiring a conventional fire alarm control panel. For industrial sites, buyers should first define the protected space, required local alarm behaviour, reporting method, power arrangement and destination-market evidence.
This page is written for industrial, warehouse and facility safety teams. It is a product-family selection resource, not a claim that every variant has the same approval, radio module or market access.

Model reference image
The image identifies a WANLIN-307 family reference. Radio, power, label and evidence scope can differ by controlled configuration; confirm the SKU/BOM before using any formal product or compliance statement.
Open the WANLIN-307 product passport · Review the public evidence center
Verified manual data
Evidence scope: WANLIN-307 user manual, Ver 1.0. Documented manual configuration only; radio, platform, power and market variants require separate SKU/BOM confirmation.
| Detection principle | Infrared photoelectric smoke sensing with MCU processing |
|---|---|
| Rated working voltage | DC 3 V |
| Battery capacity | 2400 mAh |
| Standby current | ≤ 6 μA |
| Alarm current | ≤ 100 mA |
| Sound pressure | > 80 dB(A) at 3 m directly in front |
| Operating temperature | −10 °C to +50 °C |
| Relative humidity | ≤ 95% RH at 40 °C ± 2 °C |
| Alarm output | Audible and visual alarm |
| Low-voltage indication | Below 2.7 V; indicator and one chirp about every 40 s |
| Normal indicator | Indicator illuminates about every 40 s |
| Approximate weight | 140 g including battery |
| Manual-listed execution standard | GB 20517-2006 |
| Installation reference | GB 50116-2013; final layout must follow project design requirements |
Important: “GB 20517-2006” is presented here as the execution standard stated by this manual. This wording is not a third-party certificate claim and does not establish destination-market acceptance. The manual also advises against use where relative humidity exceeds 95%, air speed exceeds 5 m/s, or heavy dust, water mist, steam, oil mist or corrosive gas is present.
Site-specific planning lens
A local-only design is simpler, while a connected design may introduce a gateway, carrier service, cloud account, commissioning procedure and ongoing network responsibility.
If the exact configuration is absent from the available evidence, mark the claim pending review instead of extending a result from another variant.
Before approving a sample, compare the model marking, sensing function, communication module, power arrangement and document revision with the purchase specification.
Existing site context: Compare Wanlin Fire fire safety management systems, technical parameters and application options for commercial, industrial and retrofit fire safety projects. Use that context to define the application; it does not replace model-specific technical or compliance review.
For this site's industrial sites focus, the planning lens is “Fire Safety Management Systems.” For export work, a product-family shortlist is only the start; the exact hardware, label, language and evidence pack must follow the selected configuration.
Last reviewed: 2026-11-02 · Reviewed by Wanlin Fire Equipment for product-family and evidence-boundary consistency.
WANLIN-303
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
WANLIN-307
Candidate configurations may include standalone, 433 MHz, LoRa, 4G or NB-IoT; availability and evidence must be confirmed per SKU/BOM.
WANLIN-309
Use when the project requires a local alarm plus a defined reporting path; verify gateway, network and destination-market requirements.
WANLIN-370
A smoke/heat/carbon-monoxide combination concept is not interchangeable with a smoke-only alarm; confirm the required sensing functions first.
Before purchase: request a model-specific evidence pack and have the destination-market requirements reviewed by a qualified local party.
Answers for buyers
No. They represent different communication paths and may use different hardware, gateways, network services and regulatory evidence. The exact SKU or BOM must be confirmed before quotation.
The importer or another qualified party familiar with the destination requirements should confirm acceptance against current documents before an order is represented as market ready.
Only if the selected hardware and product architecture support that path. Do not assume a radio module can be added to every local-only version; confirm the exact SKU/BOM and gateway requirements.
No. Remote event reporting and local audible warning are separate functions. The project specification should define both and identify who responds to remote events.
The project team should document local alarm behaviour, event buffering or retry expectations, supervision, user notification and the party responsible for restoring connectivity.
Send the destination country, application, quantity, reporting method, preferred power arrangement and required delivery schedule to wanlinfirecontrol@163.com. Recommendations and formal claims remain subject to exact-model evidence review.
Browse product information · Read technical FAQs · Contact Wanlin Fire